Why your heat pump's running cost estimate ignores standby draw

By Priya Nathan · October 22, 2026 · 7 min read
Outdoor heat pump unit installation
Photo by alpha innotec on Unsplash

I had a client on Hargreaves Street in Castlemaine email me her electricity bill last month, convinced her new heat pump was faulty. Her modelled running cost, the one on the glossy quote, said $340 a season. Her actual bill, after a mild winter with the unit barely running some weeks, came in nearer $410. She wasn't wrong to be annoyed. But the heat pump wasn't broken. Nobody had told her about standby draw.

This is the heat pump running-cost mistake almost nobody flags before install, and it's one I see on both sides of the Pacific: Australian split systems and American ducted heat pumps alike. The quote you get is built from compressor wattage at a handful of outdoor temperatures, multiplied by assumed run hours. What it almost never includes is the power the unit draws when it's technically "off."

What standby power actually is

Every heat pump, whether it's a wall-mounted split doing a bedroom or a ducted system like the Premium Inverter Ducted handling a whole house, keeps a few things alive even when you've switched it off at the remote or the thermostat. The crankcase heater is the big one in colder climates: a small resistive element that keeps the compressor's refrigerant oil warm overnight so the compressor doesn't try to start with foamed, diluted oil at 2am. There's also the control board itself, which needs to stay powered to listen for your next command, run its own clock, and in many systems maintain Wi-Fi connectivity for the app. Individually these loads are small. A crankcase heater might pull somewhere in the order of 20 to 70 watts depending on compressor size and outdoor temperature. The control board and any standby electronics might add another 3 to 10 watts. None of that sounds dramatic until you do the arithmetic on hours, not just watts.

Why the maths catches people out

Compressor run time during a cold snap looks big on paper — a few kilowatts, for a few hours a day, and the number scares people into thinking that's where all their money goes. But a heat pump isn't running flat-out continuously. In mild-to-moderate conditions, which is most of the heating season for most Australian and US climates outside the coldest belts, an inverter-driven compressor modulates down and can sit idle for long stretches between cycles. During every one of those idle stretches, if the crankcase heater is active, you're paying for it. Run the sums over a full season rather than a cold night and the picture changes. A 40-watt crankcase heater running continuously through a six-month heating season, which is common in cooler climates where the heater stays on below a threshold outdoor temperature, works out to roughly 173 kWh for the season. At a typical residential rate that's a genuine line item, not a rounding error, and it's one that essentially never appears in the capacity-based running cost table an installer hands over.

Why installers leave it off the quote

I don't think this is usually deceptive. It's a modelling shortcut. Running-cost estimates are built from manufacturer performance data at specific AHRI or AS/NZS test points, covering heating and cooling capacity against power draw at rated conditions. Standby and crankcase heater power sit in a different part of the spec sheet, usually buried in the electrical data table, and most quoting software simply doesn't pull it into the seasonal cost model. It's the same blind spot I wrote about with rated capacity shrinking in cold weather — the number on the page describes a lab condition, not your actual winter. Standby draw is the quieter cousin of that problem. Nobody's hiding it. It's just not where the quoting tools look.

Where it matters most

Standby and crankcase losses matter more in some situations than others, and it's worth knowing which camp you're in. Cold climates with long shoulder seasons are the worst case. If your crankcase heater is thermostatically controlled to switch on whenever outdoor temperature drops below a set point, and that threshold sits well above your actual heating setpoint days, the heater can be on for months even when the compressor barely runs. Minneapolis, Denver, the Victorian high country, Canberra in autumn — all places where "the heater's basically not working" and "the crankcase heater is quietly on 20 hours a day" can coexist. Multi-head systems compound it. Every outdoor unit on a multi-head system potentially has its own crankcase heater and control board draw. One outdoor unit is a rounding error. Three outdoor units serving a zoned house, each sipping standby power around the clock, adds up to a real number over a billing cycle. Oversized systems lose doubly. I've covered why oversizing quietly ruins running costs through short-cycling and poor dehumidification, but there's a standby angle too: an oversized compressor often has a bigger crankcase heater to protect a bigger oil charge, so you're paying more in idle losses for a unit that's already working against you on efficiency.

What you can actually ask for

This isn't a reason to distrust heat pumps generally, their seasonal COP still beats resistive heating and most gas systems by a wide margin on running cost. It's a reason to ask a sharper question before you sign. Ask your installer for the unit's standby and crankcase heater wattage from the technical data sheet, not the marketing brochure. Most manufacturers publish it; Mitsubishi Electric, Daikin and the US majors all list it in the engineering submittal data, it's just rarely transcribed into the customer-facing quote. Ask whether the crankcase heater is thermostatically controlled (switches on below a set outdoor temperature) or runs continuously whenever the unit is powered. The former is more efficient and what you want to see. If you're comparing two quotes with similar capacity and COP figures, this is a legitimate tiebreaker, not a technicality. A unit with a 15-watt standby draw against one with a 55-watt draw will separate by real dollars over a five-year ownership period, and it won't show up anywhere else in the comparison.

A honest caveat

I'll say the quiet part out loud: for most households in mild climates, standby draw is a genuine but secondary cost, maybe 5 to 10% on top of the compressor's own running cost. It's not going to double your bill. Where I think it actually matters is less about the dollar figure and more about trust — when an installer's number and your actual bill diverge by $70 a season and nobody can explain why, that gap erodes confidence in everything else on the quote, including the sizing and the COP claims. In my view, installers who proactively mention standby draw are usually the ones who've actually read the engineering data sheet rather than copy-pasting a brochure number, and that's worth something when you're choosing who gets the job. If you want the broader context on what heat pump quotes tend to leave out, the duct and pipe run length piece covers a parallel blind spot, and it's worth reading both before you compare quotes side by side.

Checking it yourself after install

If the system's already in, you don't need to take anyone's word for it. A plug-in power meter on a single-head split, or a clamp meter on the outdoor unit's supply for a ducted system, will show you draw when the thermostat is satisfied and the compressor isn't running. If you see a steady 30 to 60 watts with nothing audibly running, that's your crankcase heater and control board, not a fault. It's the same category of "this looks wrong but isn't" as the defrost cycle cold blast — a normal mechanism that nobody explained properly at handover. For a hot water heat pump like the Voltex MAX or ProTerra, the same logic applies to the tank's standby heat loss and any resistive backup element's parasitic draw, worth checking if your hot water bill feels higher than the EnergyGuide or energy rating label suggests it should. The Clean Energy Council's heat pump product guidance and the US Department of Energy's ENERGY STAR heat pump specifications both publish standby power thresholds as part of their certification criteria, which is a reasonable sanity check if you want to see what "normal" looks like for a certified unit before you compare it against your own meter reading.

Tagged

Common questions

Is standby power draw the same as the defrost cycle?
No. Defrost is an active heating-mode operation where the system briefly reverses to melt ice off the outdoor coil, drawing real power for a few minutes. Standby draw is the small continuous load, mainly the crankcase heater and control board, that happens while the unit is idle and the compressor isn't running at all.
Can I just switch my heat pump off at the wall to avoid standby losses?
You can, but in cold climates it removes crankcase heater protection, which can shorten compressor life or cause a rough start when you turn it back on. It's generally better to accept the small standby cost than to risk compressor damage from oil dilution on startup.
Does every heat pump have a crankcase heater?
Not necessarily. Some units, particularly smaller single-split systems rated for milder climates, skip it or use a different oil-return strategy. It's worth asking your installer directly rather than assuming, since the technical data sheet will confirm it either way.
How much does standby draw typically add to a winter power bill?
It varies by climate and unit size, but a continuously-energised 40-watt crankcase heater over a six-month heating season works out to roughly 170 kWh, which is a modest but real line item at typical residential electricity rates.
About the author
PN
Priya Nathan
Heat pumps & HVAC · Melbourne, AU

Priya covers heat pump heating, cooling and hot water systems — sizing, running costs, and what actually changes between an Australian and a US install.

Mechanical engineering background; ex-HVAC design.

More from Priya Nathan